✉ info@eieinstruments.com
Home/Shop by Category/Civil Engineering Testing Instruments/Cement Testing Instruments/Concrete Testing Instruments
Thermal Conductivity By Guarded Hot Plate Method For Aac Blocks

Thermal Conductivity By Guarded Hot Plate Method For Aac Blocks

Model Number : EIE-7013

Compliance Standards:

IS : 3346‑1966

Brief construction details:
  • EIE ‑ Thermal Conductivity Apparatus is designed to determine Thermal Conductivities of insulating materials in the form of slabs. The Apparatus consists of main central heater sandwiched between the test specimens. Cooling plates are provided on the either side of the specimen. Single identical specimen are Clamped between heaters and cooling plate. Ring guard heater ensures Uni‑directional heat flow through specimen.
Salient Features : (For single specimen testing):
  • EIE ‑ thermal conductivity test apparatus by guarded hot plate method is based on the steady‑state method and is able to measure 30 cm x 30 cm single test samples having thickness ranging from a 5 cm to 10 cm.
  • Design concept according to Indian Standard (IS : 3346‑1966) and Applicable ASTM Standard ASTM C177
  • External body is manufactured from Mild steel material, which is powder coated in attractive shades.
  • Specimen to be tested is placed in chamber such that it gets sandwiched between two heat flux sensors as per ASTM C177 guidelines.
  • Unit is equipped with 5 different thermocouples for temperature measurement on both sides of the test specimen and guard heaters.
  • Cooling is obtained by in‑built refrigeration system, which provides efficient cooling temperature as per test requirement.
  • Emerson / Kirloskar make or equivalent refrigeration system (CFC Free)
  • 7” touch screen HMI & PLC Operation
  • Linear movement (UP & DOWN) for height adjustment with the help of linear actuator
  • Facility to feed dimensions of the samples to calculate the K-value.
  • Direct reading of K-value in w/m k (No further calculation required)
  • High temperature fiber glass box Insulation (8 mm thick) along with glass wool bag Insulation around set‑up
  • Complete panel mounted electrical controls and measurement. All control accessories are within reach.
  • Operation on 230 Volts, 50 Hz, AC Supply
  • Suitable for industrial applications such as thermal conductivity measurement of AAC Blocks.
  • Temperature Range hot sideabove ambient +20 to 150° C
  • Temperature range in cold plate sidebelow ambient to +10° C
  • Thermal Conductivity measurement range0.1 to 2 w/m k
  • RefrigerantR134A - CFC Free
  • Plate Temperature ControlThrough mini-chiller system
  • Central Heater capacity500 watts, sandwiched between two copper plates
  • Central heater dimensions150 mm x 150 mm
  • Ring Guard Heater capacity1500 watts between two copper plates
  • Chiller SystemCooling chamber with circulation arrangement
  • Test specimen size30 x 30 cm in length and width and upto 50 mm thickness
  • Overall Dimensions1170 X 740 X 1000 (L X W X D) mm
  • Weight (Approx.)136 kg

Coming Soon...

Coming Soon...