Available Variants:
- Cleveland Flash Point Apparatus With Digital Temperature Indicator
- Cleveland Flash Point Apparatus With Energy Regulator
- Cleveland Flash Point Apparatus With In-Built PC – Fully Automatic – ASTM D92
Compliance Standards:
- ASTM D92
- IP 36/57
- IS 1448 (P-69)
- ISO 2592 : 2017
Key Features:
- High Accuracy
- User-Friendly Interface
- Robust Construction
- Wide Application
- Safety Compliance
- Combined wick system arrangement with gas jet or oil wick arrangement
- Automatic operation with touch screen display
- Automatic barometric pressure correction
- Interchangeable gas or electric igniter source
- Automatic flame extinguisher
- Stores more than 500 test/results
- User-defined methods and procedures
Application:
- This apparatus is used for determination of Flash Point of petroleum products except fuel oil with open flash above 80°C as per specification given in IP 36/57, IS 1448 (P:69) 1969 and ASTM-D-92-67.
- The Energy Regulator variant is used for determination of Flash Point of petroleum products with open flash between 79°C - 400°C as per specification IP 36/57, IS 1448 (P:69) 2019 and ASTM-D-92.
Significance & Use:
- Flash point is used in shipping and safety regulations to define flammable and combustible materials. Flash point can indicate the possible presence of highly volatile and flammable materials in a relatively nonvolatile or nonflammable material. The flash point is one measure of the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.
Construction Details:
- The apparatus consists of the test cup, heating plate, test flame applicator, heater and supports as described in IP and ASTM specifications.
- Complete apparatus manufactured from Brass or Stainless Steel Material.
- Heater controlled by energy regulator and temperature displayed on Digital Temperature Indicator.
- Suitable for operation on 220 Volts, 50 cycles AC mains supply.
- Aesthetic outer appearance.
- Low cost model with arbitrary control over the rate of rise of temperature.
Technical Details:
- Standalone model with touch screen display
- Easy operation with automatic test procedure and result storage
- Rapid heating procedure for high flash point
- Search programs for unknown samples
- Interchangeable gas or electric igniter source
- Automatic barometric pressure correction
- Interlocks for safe operation
- Stores more than 500 test/results
- User-defined methods/procedures
- Windows based user-friendly software
- In-built method and results storage
- 8.4” touch screen display
- LIMS compatibility with RS 232, LAN, Wi-Fi, Bluetooth and USB Ports
- Coil type heater, 450 watt @ 230VAC
- Heat rate from 1 to 20°C/min
- Centrifugal Blower 56.5 CFM, 35 watt @ 230VAC
- Stepper Motor controlled movement
- Automatic DC motor controlled swing arm
- Automatic flame extinguishing
- PT-100 Class A sample temperature sensor
- PT-100 Class A bath temperature sensor
- Ionization ring for flash detection
- Built-in pressure sensor
- Thermal sensor for fire detection
Calibration:
- Sample temperature sensor calibration
- Barometric pressure sensor calibration
Safety Interlocks:
- Temperature sensor defect detection
- Flash detector defect detection
- Electric igniter failure detection
- Test stop above expected Flash Point or at 400°C
- Fire detection with warning buzzer and power cut-off
- Arm position detection